Send Message
Zhuzhou Ruideer Metallurgy Equipment Manufacturing Co.,Ltd 86--16673365810 shirley.xiao@zzrde.com
Higher Wear Resistance Integrated CVD Coating Machine For CNC Carbide Tools

Higher Wear Resistance Integrated CVD Coating Machine For CNC Carbide Tools

  • High Light

    Integrated CVD Coating Machine

    ,

    Wear Resistant CVD Coating Machine

    ,

    CNC Carbide Tools CVD Coating Equipment

  • Reaction Chamber
    2 Pcs
  • Maximum Temperature
    1100℃
  • Working Temperature
    900-1050°C
  • Total Power
    About 75KW
  • Heating Power
    About 55KW
  • Effective Size Of Reaction Chamber
    φ500mm×1500 Mm;
  • Place of Origin
    China
  • Brand Name
    Ruideer
  • Certification
    GB150, JB4732
  • Model Number
    530L
  • Minimum Order Quantity
    1 set
  • Price
    USD1200000.00-20000000.00
  • Packaging Details
    Special wooden box
  • Delivery Time
    5-8 months
  • Payment Terms
    T/T
  • Supply Ability
    3 sets

Higher Wear Resistance Integrated CVD Coating Machine For CNC Carbide Tools

Integrated CVD Coating Furnace for CNC Carbide Tools with Higher Wear Resistance

 

1. Assembly Group

The CVD coating furnace consists of six parts: workbench, reaction chamber, heating cover, cooling cover, rail crane, condenser.

 

The major systems are cooling water system, pump system, gas tube&pipeline system, aerodynamic system and electrical control system.

 

2. Factory working environment

2.1 Ambient humidity and temperature

2.1.1 Ambient humidity: <90% (at +35°C)

2.1.2 Ambient temperature: 5℃~40℃

2.2 Power supply

2.2.1 Power supply: 380V±10%, 50Hz, three-phase five-wire system

2.2.2 Control power supply: 210V~250V, 50Hz, single phase

2.3 Air source

2.3.1 Compressed air pressure: 6-7bar,

2.3.2 Ar pressure: 2-3bar,

2.3.3 H2 pressure and flow: 2-3bar, 0-75slm

2.3.4 N2 pressure and flow: 2-3bar, 0-50slm

2.3.5 CO pressure and flow: 2—3bar, 0-2.5slm

2.3.6 CO2 pressure and flow: 2-3bar, 0-5slm

2.3.7 CH4 pressure and flow: 2-3bar, 0-5slm

2.3.8 HCl pressure and flow: 2-3bar, 0-5slm

2.3.9 H2S pressure and flow: 2-3bar, 0-0.4slm

2.4 Water source

2.4.1 Cooling water inlet pressure: 2-3bar, pure water is recommended. The temperature is 13-16°C. (Customers need to be equipped with chilled water), cooling water flow, 5m3/h.

2.4.2 Emergency standby water source (to be prepared by the user)

Pressure: 1.5bar—2bar.